Filters

Filters

Manufacturers

Yes

Volume

d 1

Height

length

Width

d 2

Sterile

Type

    0.2 ml PCR Real Time tubes in strips 4094.5BP

    deltalab

    Tubes made of polypropylene. Strip of 8 tubes, each one featuring an attached flat cap.
    Strips are manufactured by biomaterial molding, so the tubes are made of opaque white PP, while caps are compounded of transparent, optically clear PP.
    Opaque white tubes perform the highest performance in Real Time PCR, as they avoid crosstalking between wells.
    Specially conceived for Real Time PCR. Caps are easily pierceable. Certified RNAse, DNAse, DNA and PCR inhibitors free.

    0.2 ml PCR tubes 4094.1

    deltalab

    Tubes made of polypropylene, featuring attached hinged caps. Caps are flat and easily pierceable.
    See strips of these tubes on the following page (codes 4094.3N and 4094.4N).
    Certified RNAse, DNAse and PCR inhibitors free.

    0.2 ml PCR tubes in strips 4095.2

    deltalab

    Made of natural colour polypropylene. Different models available:
     - Strip of 8 or 12 tubes with its corresponding strip of 8 or 12 domed caps.
     - Strip of 8 tubes with its attached hinged strip of domed caps.
     - Strip of 8 tubes with its attached hinged strip of flat caps, suitable for Real
     Time PCR.
     - Strip of 8 tubes.
     - Strip of 8 flat caps, suitable for Real Time PCR.
     Cap and tube strips allow easy handling and inventory of tubes and caps. Cap
     strips prevent cross-contamination from tube to tube.
     Code 4095.7N is also suitable for plates.Certified RNAse, DNAse and pyrogen
     free.

    Code: 4095.2N - strip of 8 tubes with domed caps
    Code: 4095.7N - strip of 8 flat caps
    Code: 4095.6N - strip of 8 microtubes
    Code: 4095.1NP - strip of 8 tubes with flat caps
    code: 4095.1N - strip of 8 tubes with dome caps attached
    code: 4095.4N - strip of 12 tubes with domed caps

    1.5 ml safety lock microtubes 4092.4N

    deltalab

    Made of ultra clear polypropylene. Feature a special “snap-seal” secure lock.
    A special locking clasp with a distinctive audible snapseal design ensures tubes will not open during centrifugation. Tubes have a frosted writing surface on side and on attached closure for better sample identification.
    Caps are easy to handle and can be opened and closed with one hand. Lids are easily pierceable. Tubes have moulded-in graduations in 0.5 ml increments.
    Autoclavable.
    Withstand centrifugation up to 15,000 xg.

    150 ml containers (57 x 73 mm) 4097

    deltalab

    Ultra clear polypropylene containers with polyethylene leak proof screw caps.
     Moulded graduation in 20 ml increments up to 100 ml. Frosted panel on side for easy writing.
     Standard colour of the cap: red.

    50 ml centrifugal tubes skirted 42995х

    deltalab

     Made of polypropylene, suitable for both clinical and research applications.
     DNAsa, RNAsa and pyrogen free.
     They are also free from natural rubber and heavy metals.
     High transparency of the material for a clear visualization during experiments specially for molecular biology.
     Tube and cap designed with the system of flat threads for a complete leakproof.
     Highly smooth hydrophobic surface for minimum disturbance during centrifugation.
     Silk-screen blue graduation in the tube and large white frosted portion for easy writing.
     Autoclavable at 121 ºC.
     Centrifugation resistance: 14.000 xg, except code 429931: 7.000 xg and codes 429950, 429951: 3.500 xg
     It is recommended to use adapters to centrifuge and avoid malformations.
     Available models: 15 ml non-skirted and 50 ml skirted and non-skirted. 

    Anesthetic Syringe, stainless steel 1075

    VETRO DESIGN SRL

    The PRIMA anesthesia syringe, made of stainless steel, has 2 tips: metric and inch screw, 3 rings, with manual suction thanks to the spiral-shaped system. The syringe is used to administer local anesthesia. Instructions for use: 1. Sterilize the syringe in the autoclave and remove it from the bag after the sterilization is completed; 2. Hold the syringe in your left hand and completely withdraw the piston rod 3. With the piston rod withdrawn, place the anesthetic cartridge in the syringe body. 4. The rubber plug must be inserted first. 5. Once the cartridge is in place, release the piston rod. 6. Engage the cartridge and the harpoon by placing moderate pressure on the ring bar with the help of your thumb. 7. Do not hold your hand on the cartridge while holding the harpoon (for safety). 8. After completing the procedure, unscrew the needle (it must have the protective cap on). 9.Retract the piston to release the harpoon from the cartridge. 10. Remove the cartridge from the syringe by pulling back the ring with the help of your thumb. 11. Throw the cartridge and needle into the sharps waste container.

    Biopsy cassette 0319/1000

    Kaltek S.r.l.

    Embedding cassettes for biopsies, with small holes and detachable lid, created to contain very small specimens.
    Made of acetylic resin, resistant to most solvents, decalcifying solutions and ultrasounds.
    The biopsy cassettes can be used also with microwave or vacuum embedding techniques.
    Provided with triple closure system and three writing sides.
    Compatible with most automatic printers.
    Available in various colors for a more rational classification.

    Biopsy embedding cassettes Micromesh™ 55535

    deltalab

    This modified version of the MICROMESH™ offers 1.676 square openings (0,38mm) allowing for a greatly improved fluid exchange without having to use biopsy pads. Large anterior and posterior slots in both cassette and cover ensure that the MICROMESH™ biopsy cassette will sink rapidly. A large square compartment measuring 27 mm is perfect even for needle biopsies. The cover does not protrude above the cassette, a great space saving feature allowing more cassettes to be stacked in automatic labeling machines and tissue processors.
    Molded from a special high density polymer, these patented cassettes keep specimens safely submerged in liquid and are totally resistant to the chemical action of histological solvents. The MICROMESH™ mesh ensures efficient fluid exchange and drainage. The one-piece integral lid eliminates the need for separate steel lids. They can be opened and closed as often as necessary and they always relock securely without danger of specimen loss. Large labeling areas are located on three sides of the cassettes. Anterior writing area is at a 45° angle to make the cassette more suitable to be used with automated cassette printers.

Моля изберете желания от вас продукт от дадената категория!

Product added to cart

See Cart